Crown Selection Procedures

If you wish, you can use the Sizing Software which will take your information and automatically suggest the correct Crown Model

 

This will show you how to Select the Correct Crown Drive for your application.

1. Determine Your Preferred Input/Output Ratio. Standard ratios are 1:1 and 2:1. It is also possible to use a ratio of 1:2 by using shaft #2 as the input shaft.

2. Designate Which Shafts Are To Be Input And Output Shafts.
This step is especially important to determine that no shaft will turn faster than 2000 RPM. If shaft #2 in the 2:1 ratio models is selected as the input shaft, it can turn at a maximum of 1000 RPM. In the 1:1 ratio models it makes no difference. However, the choice in either case will affect your mounting.

3. Choose Drive Type.
Choose from 2-way or 3-way or Counter Rotating configurations.

4. Be Certain That The Designated Output Shaft Has A Torque Capacity Greater Than Your Applications Load.

Click to see the tables for two and three way

Click to see the tables for Counter Rotating

Be sure to apply the service factors from the chart to the right.

5. Select The Correct Model Number.

Click to see dimensions for 2-Way

Click to see dimensions for 3-Way

Click to see dimensions for Counter Rotating

Note that units with 3/8 inch shafts have flats and units with 1/2, 5/8, 3/4 and 1 inch shafts have standard keyways. Also note that 1 inch shaft models are available in 3-way type only.

6. If modifications of shafts and/or housings are required for your application, send a drawing and a description of the application to the factory.


Service Factors
The Service factors listed below will cover most usual applications. Applications dealing with single and multi-cylinder internal combustion engines, extreme repetitive shock loads, and high energy loads are not covered.

For additional information, please contact the factory.
Determine Prime
Mover
Determine Duration
of Service
Driven Machine
Load Classifications
Uni-
form
Mod Shock Heavy Shock
Electric
Motor,
Steam
Turbine
or
Hydraulic
Motor
Occasional
1/2 hr. /day
.50 .80 1.25
Intermittent
3 hrs./day
.80 1.00 1.50
Over
3 hrs. up to 10 hrs./day
1.00 1.25 1.75
Over
10 hrs./day
1.25 1.50 2.00

 


The right to make engineering refinements on all products is reserved.
Dimensions and other details subject to change.
When dimensions are critical, detailed drawings should be obtained from the factory.

Send mail to zero-max@zero-max.com with questions or comments about this web site.
13200 Sixth Avenue North • Plymouth, MN 55441
1-800-533-1731 • 763-546-4300 • Fax:763-546-8260

Copyright© 2007 Zero-Max, Inc.